Anybus programming interface

The PSC-ANY unit extends the interfacing capabilities of power supplies equipped with an analog programming interface. It acts as a carrier for Anybus® CompactCom M40 pluggable inserts, each supporting a different communication protocol. In this way, a power supply with an analog programming interface can expand its communication capabilities to other protocols, depending on the Anybus M40 insert plugged into the PSC-ANY unit.

 

The PSC-ANY can be configured via a USB interface, either through a terminal-based console or by using SCPI commands. Its main function is to translate data between the analog interface of a power supply and one of the supported Anybus inserts, each offering a different communication protocol. In addition to configuration-type SCPI commands, programming and monitoring commands are also available. This allows the PSC-ANY to function either as an Anybus carrier programming interface or as an analog-to-USB programming interface.

 

The Anybus® inserts are manufactured by HMS Industrial Networks AB. These inserts enable safe, fast, and reliable industrial communication, making integration into automation networks easier than ever. They can be ordered directly from Delta Elektronika, from HMS, or through third-party suppliers. The supported Anybus inserts are listed below. For more details about the Anybus Interface Unit, please refer to the datasheet below. The external interface unit can be mounted in a 19" rack front. For more information, see the datasheet or the 19"-rack adapter page.
 

Supported inserts and protocols

Our Anybus Interface Unit in combination with HMS's Anybus inserts supports a wide range of industrial communication protocols, ensuring compatibility with various automation systems.

 

The following Anybus inserts and protocols are supported:

  • CANopen (AB6613)
  • EtherCAT (AB6607)
  • EtherNet/IP (AB6604)
  • Modbus-TCP (AB6603)
  • PROFIBUS (AB6600)
  • PROFINET (AB6605)

The numbers between the brackets are the item numbers from HMS and uniquely identify, the Anybus inserts. See the options section below to see the combinations of the PSC-ANY-EXT with an Anybus insert.

 

To see what USB SCPI commands are available, please see the PSC-ANY-EXT product manual. To see what power supply parameters can be programmed using an Anybus insert, please see the Fieldbus implementation guide.

Features

  • Programming & Monitoring resolution 16 bit
  • Read-back of status signals
  • Programming & Monitoring accuracy ± 0.01%
  • Software Calibration
  • SCPI commands
  • User console
     

Functionalities

  • Carrier for Anybus M40 inserts, each enabling a different protocol
  • Interface between Anybus insert and analog programmed power supply
  • Power supply programming over analog programmed power supply
  • Power supply monitoring over analog programmed power supply
  • Additionally, USB SCPI programming and monitoring of power supply

Specifications

  • Programming and monitoring resolution: 16 bit
  • Linearity error: +/- 2 LSB (prog.), +/- 1 LSB (mon.)
  • Input voltage: 98-264 V AC (48-62 Hz)
  • Insulation inputs / outputs to case: 600 VDC

Standards

  • Generic Emission: EN 61326-1 (class B equipment, for use in domestic establishment)
  • Generic Immunity: EN 61326-1 (equipment for use in industrial and domestic establishment)
  • Safety: EN 60950 / EN 61010
  • Protection class: IP20
     

Dimensions and weight

  • Width: 100 mm
  • Height: 91 mm
  • Depth: 125 mm
  • Weight: 0.6 kg
PSC ANY EXT-AA
PSC ANY EXT-VA

Options

Optional factory-installed features

Icon-Anybus Interface2

Anybus-carrier unit + CANopen Insert

Combination of the Anybus-carrier unit with a CANopen Insert

Icon-Anybus Interface2

Anybus-carrier unit + EtherCAT Insert

Combination of the Anybus-carrier unit with an EtherCAT Insert

Icon-Anybus Interface2

Anybus-carrier unit + EtherNet/IP Insert

Combination of the Anybus-carrier unit with an EtherNet/IP Insert

Icon-Anybus Interface2

Anybus-carrier unit + Modbus-TCP Insert

Combination of the Anybus-carrier unit with a Modbus-TCP Insert

Icon-Anybus Interface2

Anybus-carrier unit + PROFIBUS Insert

Combination of the Anybus-carrier unit with a PROFIBUS Insert

Icon-Anybus Interface2

Anybus-carrier unit + PROFINET Insert

Combination of the Anybus-carrier unit with a PROFINET Insert

Support items

Order codes

Codes for reference

 

To order codes

Distribution network

Find a distributor in your region

 

To distributors

Firmware updates

Receive firmware update notifications

 

Subscribe

 

Downloads

Data sheets Type/Format Size
Data sheet Anybus-carrier interface unit pdf 325.89 KB
Manuals Type/Format Size
Product manual Anybus-carrier interface unit pdf 3.13 MB
Guides Type/Format Size
Anybus Fieldbus Implementation Guide pdf 647.02 KB
Device description files Type/Format Size
CANopen EDS Data Format A zip 2.01 KB
EtherCAT ESI Data Format A zip 6.21 KB
Ethernet/IP EDS Data Format A zip 39.4 KB
POWERLINK XDD Data Format A zip 9.05 KB
PROFIBUS GSD Data Format A zip 3.09 KB
PROFINET GSDML Data Format A zip 5.92 KB