• English
    • Nederlands
    • Deutsch
    • Franšais
    • Espa˝ol

MASTER/
SLAVE
INTERFACE
SM15K.

INT MOD M/S 2

Features:

    • For applications where more current is required than 1 SM15K unit can deliver
    • Optimal dynamic response in parallel operation
    • Fast reaction time: up to 250 uSec

Functionalities:

    • Multiple power supplies behave as one large system
    • All information visible on master
    • For SM15K series only and max. 1 pc INT MOD M/S 2 per unit possible
    • Master/Slave parallel operation SM500-CP-90, SM1500-CP-30: up to 60 units (identical)
    • Max. 6 units SM70-CP-450 in parallel operation
    • Max. 6 units SM500-CP-90 in series operation
    • Series operation not possible for SM70-CP-450 and SM1500-CP-30
    • Installation in slot 3 or 4 only (rear end of power supply)
    • Easy to plug in or remove by user at site

Specifications:

Operating temperature : -20 to +50 ║C

Standards:

Safety : EN 60950 / EN 61010

 

Dimensions and weight:

Width = 25 mm

Height = 77 mm

Depth = 77 mm

Weight = 70 gr

 

Plug and Play module

Options:

  • Master/Slave assembly kit SM15K

    Connection sets for Master/Slave set-ups using the M/S PAR and the M/S SER assembly kits.

     

    SM70-CP-450

      • M/S PAR SET A2 — for 2 units in parallel
      • M/S PAR SET A3 — for 3 units in parallel
      • M/S PAR SET A4 — for 4 units in parallel
      • M/S PAR SET A5 — for 5 units in parallel
      • M/S PAR SET A6 — for 6 units in parallel
     

    SM210-CP-150, SM500-CP-90 and SM1500-CP-30

      • M/S PAR SET C2 — for 2 units in parallel
      • M/S PAR SET C3 — for 3 units in parallel
      • M/S PAR SET C4 — for 4 units in parallel
      • M/S PAR SET C5 — for 5 units in parallel
      • M/S PAR SET C6 — for 6 units in parallel
      • M/S PAR SET C7 — for 7 units in parallel
      • M/S PAR SET C8 — for 8 units in parallel
      • M/S PAR SET C9 — for 9 units in parallel
      • M/S PAR SET C10 — for 10 units in parallel
      • M/S PAR SET C11 — for 11 units in parallel
      • M/S PAR SET C12 — for 12 units in parallel
      • 13 to 20 in parallel  — see application note
     
    SM500-CP-90
      • M/S SER SET BA — for 2 units in series
      • M/S SER SET BB — for 3 to 6 units in series
     
    Download below application notes for instructions:
Firmware
Update if current version > P0109 -
Upgrade if current version ≤ P0109 -
Technical documents
Data sheet DATA_SHEET_MASTER_SLAVE_INTERFACE_SM15K.pdf
Product manual MANUAL_INTERFACES_SM15K.pdf
Application notes
Application note -
Software
Software -
Product Support

 

T: +31 111 413656
E: by filling out the contact form

 

Contact form
Sales Department

 

T: +31 111 413656
E: by filling out the contact form

 

Contact form